The institute
FEMTO's news

A new source of infrared light thanks to fibre optic cascades

Scientists from  FEMTO-ST Institute and McGill University (Montreal, Canada) have designed and developed in collaboration with three French companies a light source covering the entire mid-infrared wavelength range: from 2 to 10 µm. This work, which is published in Laser and Photonics Reviews , opens up applications in spectrometry and biomedical imaging.

See the CNRS article

Fiber-based supercontinuum1 (SC) light sources have become enormously useful in the last decade for a wide range of industrial and scientific applications. New uses are constantly emerging due to their unique optical properties that combine high brightness, multi-octave frequency bandwidth, inherently fiber delivery and single-mode output. Applications include optical coherence tomography (OCT), material processing, chemical sensing, gas monitoring, broadband imaging, and absorption spectroscopy. State-of-the-art SC lasers are based on silica-glass microstructured optical fibers, providing watts of output power over the bandwidth 0.4-2 µm. However, many applications such as detection of chemical and biological species would benefit from extending the SC spectrum beyond the state-of-the-art, in particular towards the mid-infrared (IR) range. This currently motivates significant research effort focused on extending the wavelength coverage towards the 2 to 20 µm molecular fingerprint region.

Various infrared soft glasses based on chalcogenide, tellurite, telluride, heavy-metal oxide and fluoride have been used for drawing highly nonlinear fibers for the mid-infrared, and experiments have shown efficient mid-IR SC generation up to 14 µm in chalcogenide optical fibers and up to 16 µm in telluride fibers. However, most of these mid-IR SC sources have been demonstrated using bulky and expensive mid-IR pump sources such as optical parametric oscillators and amplifiers, making them impractical for most abovementioned applications.

Now writing in Laser and Photonics Reviews, S. Venck and coworkers (SelenOptics) report a compact all-fiber cascaded system which provides a supercontinuum emission spanning the entire 2-10 µm mid-infrared range, thus offering a new reliable laser solution for molecular spectroscopy, remote sensing, optical coherence tomography, and hyperspectral imaging. To get this broad continuous spectrum, they developed a more practical and elegant solution based on a cascaded silica-fluoride-chalcogenide fiber system directly pumped by a compact pulsed fiber laser at a wavelength of 1.55 µm. The initial laser spectrum was progressively broadened and redshifted in the three cascaded fibers through nonlinear optical effects, enabling a stepwise extension towards the mid-infrared. This all-fiber system was shown to generate a nearly flat broadband mid-infrared continuous spectrum from 2 µm to 10 µm (See Figure 1), the upper transmission limit of the chalcogenide fiber, with several tens of milliwatts of output power.

T.Sylvestre (FEMTO-ST), who managed the project with SelenOptics, says argues:“This simple technique paves the way for low cost, practical, and robust broadband sources for mid-IR sensing and spectroscopy. Nothing expect the synchrotron radiation can give wider bandwidth”. The authors further describe in their paper a fully-realistic numerical model used to design the fibers and to simulate the nonlinear pulse propagation through the cascaded fiber system and they use numerical results to discuss and optimize the physical processes underlying the spectral broadening in the cascaded system. The teams concur that their mid-infrared supercontinuum source is now ready for commercialization and they are working on ways forward.

This work involves researchers from the FEMTO-ST institute, The McGill University in Montréal (Canada) and three French companies ( SelenOptics, Le Verre Fluoré, Leukos) and is the result of a European H2020 Marie-Curie ITN project under grant agreement 722328, managed by CNRS.

https://doi.org/10.1002/lpor.202000011

Contact : Thibaut Sylvestre

  • Coup de projecteur sur le Président de l'année internationale de la lumière

    Le service sciences, arts et culture de l’Université de Franche-Comté a décidé de mettre un coup de projecteur sur John Dudley, chercheur à l'institut FEMTO-ST et Président de l'année internationale de la lumière 2015

    Read more
  • Conférence « Un Tsunami numérique sur l’éducation, vraiment ?

    Mercredi 3 juin à partir de 13h30, dans le cadre d'une conférence qui se déroulera dans le locaux de l'ENSMM et en interactivité, Emmanuel Davidenkoff,Spécialiste de l’éducation et de son évolution interpelle sur l’émergence d’une véritable société numérique.

    Read more
  • Best Paper Award à ICRA 2015

    L'équipe CODE (département AS2M) vient de remporter le Best Automation Paper Award à ICRA 2015 pour un nouveau concept de manipulation et de transport sans contact de wafers et de cellules solaires.

    Read more
  • Auréa Technology récompensée !

    Auréa Technology, Spin-off de FEMTO-ST, gagnante du prix international de l'innovation 2015 CLEO-Laser Focus world

    Read more
  • La lumière s’invite à l’hôpital d’enfants de Brabois CHRU de Nancy

    Le temps d’une émission télévisée sur télé 8, Luc Froehly, chargé de recherche CNRS au département d’optique de FEMTO-ST explorera la thématique de la LUMIÈRE avec les enfants hospitalisés de CHRU de Nancy, mardi 12 mai 2015, de 14h à 16h.

    Read more
  • Le projet I-SITE UBFC pré-sélectionné

    Le projet I-SITE de l'Université Bourgogne-Franche-Comté (UBFC) pré-sélectionné...

    Read more
  • FEMTO-ST remet un prix spécial au concours C.Génial 2015

    Nicolas Chaillet, Directeur de FEMTO-ST a remis aux collégiens du collège Collucci le Prix spécial « Année de la lumière en France » pour le projet « Image JAILLISSANTE pas si LED »

    Read more
  • Un prix au forum des microscopies à sonde locale 2015

    Gaolei Zhan a obtenu le second prix du meilleur poster lors forum des microscopies à sonde locale 2015.

    Read more
  • Observation de l'éclipse solaire - 20 Mars 2015

    À l'occasion de l'éclipse partielle du Soleil, l'observatoire de Besançon et l'Association astronomique de Franche-Comté proposent une matinée d'observations pour profiter au mieux du spectacle.

    Read more
  • Concours "Ma thèse en 180 secondes"

    180 secondes pour faire partager votre passion. 180 secondes pour expliquer clairement les enjeux de votre thèse. 180 secondes pour convaincre le jury. 180 secondes pour résumer plusieurs années de travail. 180 secondes pour vous qualifier pour la finale nationale. Voilà le challenge du concours « Ma thèse en 180 secondes » (MT180 pour les intimes).

    Read more